1,171 to 1,180 of 1,329 Results
Gzip Archive - 987.2 MB -
MD5: 8fa87d92ab71ef894683e58a4cf8a3b7
Raw ultrasonic measurement data of the large samples in *.psdata and *.csv file format. File name schema:
maximum applied temperature in degree Celsius;
cooling protocol ("slow" or "fast");
measurement date ("t0" = before thermal treatment, "t1" = after thermal treatment);
transducer type ("P-wave_1.0MHz" or "S-wave_1.0MHz");
optional: polar a... |
Gzip Archive - 2.8 GB -
MD5: 207f8874db2dd6c60f56fa516e55d2e2
Raw ultrasonic measurement data of the medium samples in *.psdata and *.csv file format. File name schema:
maximum applied temperature in degree Celsius;
cooling protocol ("slow" or "fast");
measurement date ("t0" = before thermal treatment, "t1" = after thermal treatment);
transducer type ("P-wave_1.0MHz" or "S-wave_1.0MHz");
optional: polar... |
Tabular Data - 15.9 KB - 35 Variables, 66 Observations - UNF:6:joJF3aozdn29i9JuMO+MQA==
Shear wave polar measurements for all samples in *.csv file format. Up to the reference samples, all measurements are related to the state after the thermal treatment was applied. The respective polar angle phi is specified in the header. E.g., "phi022.5deg" means a polar angle of phi = 22.5 deg. |
Tabular Data - 6.2 KB - 12 Variables, 66 Observations - UNF:6:vKEsnWStckpnsQZKJ/0FMw==
Measured and derived absolute quantities for all samples before ("t0") the thermal treatment was applied in *.csv file format. |
Tabular Data - 6.4 KB - 12 Variables, 66 Observations - UNF:6:q8dgOib7iAe43LWQnrhqAQ==
Measured and derived absolute quantities for all samples after ("t1") the respective thermal treatment was applied in *.csv file format. |
Tabular Data - 7.4 KB - 12 Variables, 66 Observations - UNF:6:BGT8Hv1L8ZJU4xWZJTT9Ig==
Relative change of the measured and derived quantities ("processed_data_absolute_values_t0.csv", "processed_data_absolute_values_t0.csv") for all samples due to the thermal treatment in *.csv file format. |
Mar 1, 2022 - Subarea A7
Potyka, Johanna; Kromer, Johannes, 2022, "Efficient three-material PLIC Implementation as Fortran Module", https://doi.org/10.18419/DARUS-2488, DaRUS, V1
The dataset provides a Fortran module with the code for the efficient three-phase positioning method. |
Fortran Source Code - 81.4 KB -
MD5: d4a7e39782d75e836f75c89441dd8e47
Fortran module, implementation of sequential efficient three-material PLIC positioning |
Gzip Archive - 1.4 GB -
MD5: 1cd77dc2fc37ebb7b6640dfc6c7f8747
Projection images (360 deg, angle increment 0.25 deg), dark image (di) and open beam image (ob) in 16 bit *.tif file format. Preload F_stat. = 400 N. |
Gzip Archive - 992.7 MB -
MD5: ce3904add33d71fdc31bab47d24b2000
Reconstructed micro-XRCT data set in 16 bit *.tif file format. 972x972x768 voxels with the uniform voxel size of 110 µm. Preload F_stat. = 400 N. |