The effectiveness of bone-cement injection during vertebroplasty is highly dependent on the cement-injection-distribution pattern, the interface effects between the porous bone structure and the initially liquid cement, as well as the curing process of the bone cement itself. Taking vertebroplasty as motivation, this project aims at taking into account interface and material deposition processes on the pore scale to describe material-injection processes in porous media on the REV (representative elementary volume) scale. The modelling process will be exemplified on vertebra-like structures.
Featured Dataverses

In order to use this feature you must have at least one published or linked dataverse.

Publish Dataverse

Are you sure you want to publish your dataverse? Once you do so it must remain published.

Publish Dataverse

This dataverse cannot be published because the dataverse it is in has not been published.

Delete Dataverse

Are you sure you want to delete your dataverse? You cannot undelete this dataverse.

Advanced Search

1 to 10 of 124 Results
May 15, 2024
Trivedi, Zubin; Wychowaniec, Jacek K.; Gehweiler, Dominic; Sprecher, Christoph Martin; Boger, Andreas; Gueorguiev, Boyko; D'Este, Matteo; Ricken, Tim; Röhrle, Oliver, 2024, "Data for: Rheological Analysis and Evaluation of Measurement Techniques for the Curing Polymethylmethacrylate Bone Cement in Vertebroplasty", https://doi.org/10.18419/darus-4004, DaRUS, V1, UNF:6:qWipgRgsaAlTQZDkmPv0LQ== [fileUNF]
This dataset includes the measurement data described in the paper "Rheological Analysis and Evaluation of Measurement Techniques for the Curing Polymethylmethacrylate Bone Cement in Vertebroplasty" and additional supplementary data. All data in .csv files except 'Inj1 -- 5' are g...
Comma Separated Values - 9.4 KB - MD5: 8989dc14d8bb7cb8ee93faecba1c58ca
Oscillatory test at 3 mNm torque amplitude and 1 Hz frequency (Fig.S1)
Comma Separated Values - 9.4 KB - MD5: ae3c5e6526bf87c7aa2a190ee3981ff1
Oscillatory test at 3 mNm torque amplitude and 1 Hz frequency (Fig.S1)
Comma Separated Values - 9.5 KB - MD5: 2af262e270ef4bf66e273ed8ab0a2fc3
Oscillatory test at 3 mNm torque amplitude and 1 Hz frequency (Fig.S1)
Comma Separated Values - 9.5 KB - MD5: 9292948e5115ca3f154d55849e9b2a5c
Oscillatory test at 3 mNm torque amplitude and 1 Hz frequency (Fig.S1)
Tabular Data - 26.7 KB - 2 Variables, 1582 Observations - UNF:6:9FvbgiUvM5buhRa0GNwedg==
Injection test at 0.025 mL/s (Fig. 7a, 7b)
Tabular Data - 13.4 KB - 2 Variables, 801 Observations - UNF:6:cQ5ceGSSFGO8pYiQF6aOlg==
Injection test at 0.05 mL/s (Fig. 7a, 7b)
Tabular Data - 6.6 KB - 2 Variables, 410 Observations - UNF:6:ZzKVSTLgyvim0f/NBcdNrA==
Injection test at 0.1 mL/s (Fig. 7a, 7b)
Tabular Data - 3.4 KB - 2 Variables, 215 Observations - UNF:6:JYYhuJ9dufRqnC+G5/wyqw==
Injection test at 0.2 mL/s (Fig. 7a, 7b)
Tabular Data - 1.9 KB - 2 Variables, 117 Observations - UNF:6:yXUKoRIus24AzLU1n4Ho7w==
Injection test at 0.4 mL/s (Fig. 7a, 7b)
Add Data