Featured Dataverses

In order to use this feature you must have at least one published or linked dataverse.

Publish Dataverse

Are you sure you want to publish your dataverse? Once you do so it must remain published.

Publish Dataverse

This dataverse cannot be published because the dataverse it is in has not been published.

Delete Dataverse

Are you sure you want to delete your dataverse? You cannot undelete this dataverse.

Advanced Search

11 to 20 of 117 Results
Comma Separated Values - 44.0 KB - MD5: 1ad7cdff57dc4118ac4d54cb6cdb746d
Oscillatory deformation of 0.2\% strain amplitude and 1 Hz frequency for 30 minutes (Fig. 2a)
Comma Separated Values - 45.3 KB - MD5: 50cc5064c071dda20253a4a937b58171
Oscillatory deformation of 20\% strain amplitude and 1 Hz frequency for 30 minutes (Fig. 2b)
Comma Separated Values - 22.0 KB - MD5: 231dd05549ef62ca6db460879603863f
Oscillatory deformation in three stages: (i) 0.1\% strain amplitude, 0.1 Hz (5 mins) (ii) 20\% strain amplitude, 1 Hz (3 mins) (iii) 0.1\% strain amplitude, 0.1 Hz (22 mins) (Fig. 2c)
Comma Separated Values - 10.5 KB - MD5: 11c0f4f8a5608380fd77c2224195a077
Oscillatory deformation in three stages: (i) 0.1\% strain amplitude, 0.1 Hz, 23 °C (5 mins) (ii) 20\% strain amplitude, 1 Hz, 23 °C (3 mins) (iii) 0.1\% strain amplitude, 0.1 Hz, 37 °C (22 mins) (Fig. 2d)
Comma Separated Values - 13.6 KB - MD5: 38cfcc5e7a8ce3266be6fc8c08e663bd
Rotational shear stress was applied in steps of (i) 0 Pa (ii) 100 Pa (iii) 0 Pa (iv) 500 Pa (v) 0 Pa (vi) 2000 Pa (vii) 0 Pa, of one minute each, to evaluate creep behaviour. (Fig. 3a)
Comma Separated Values - 13.7 KB - MD5: 8df10ee0d241e3c0dc7691027a46066f
Rotational shear strain was applied in steps of (i) 0\% (ii) 1\% (iii) 0\%, of two minutes each. (Fig. 3b)
Comma Separated Values - 12.8 KB - MD5: 51ab666159b6260f569baf2f3e5f7c2f
Rotational shear strain was applied in steps of (i) 0\% (ii) 100\% (iii) 0\%, of two minutes each. (Fig. 3b)
Comma Separated Values - 10.6 KB - MD5: 1f038eae89de2e048231fbce416e37b5
Amplitude sweep test, where the strain amplitude was gradually increased from 0.01\% to 1000\%. The test was done at 1 Hz frequency (Fig. 3c, 3d)
Comma Separated Values - 19.9 KB - MD5: 2148cf17656ea3d56bbc388547e5ec03
Amplitude sweep test, where the strain amplitude was gradually increased from 0.01\% to 1000\%. The test was done at 1 Hz frequency (Fig. 3c, 3d)
Comma Separated Values - 59.2 KB - MD5: 764145a3c548242cca5883063f9a3e9d
Amplitude sweep test, where the strain amplitude was gradually increased from 0.01\% to 1000\%. The test was done at 1 Hz frequency (Fig. 3c, 3d)
Add Data

Log in to create a dataverse or add a dataset.

Share Dataverse

Share this dataverse on your favorite social media networks.

Link Dataverse
Reset Modifications

Are you sure you want to reset the selected metadata fields? If you do this, any customizations (hidden, required, optional) you have done will no longer appear.