1 to 8 of 8 Results
Apr 5, 2023 - Publication: Crystalline rocks
Ruf, Matthias; Lee, Dongwon; Steeb, Holger, 2023, "In situ performed fracturing experiment of a limestone sample using an X-ray transparent triaxial cell: micro-XRCT data sets and measurement data", https://doi.org/10.18419/darus-3106, DaRUS, V1, UNF:6:jZuOGs6RP72PrLA8cCwFjg== [fileUNF]
This dataset contains in situ recorded micro X-ray Computed Tomography (micro-XRCT) scan data sets (reconstructed and projection images) of a marine limestone sample under different triaxial loading conditions. The loading conditions were applied to establish the initial conditio... |
Jul 12, 2022 - Publication: Enzymatically induced carbonate precipitation
Ruf, Matthias; Hommel, Johannes; Steeb, Holger, 2022, "Enzymatically induced carbonate precipitation and its effect on capillary pressure-saturation relations of porous media - micro-XRCT dataset of low column (sample 10)", https://doi.org/10.18419/darus-2908, DaRUS, V1, UNF:6:lD3UlWjZQRaGPURMuWejpw== [fileUNF]
This dataset contains a micro X-ray Computed Tomography (micro-XRCT) data set (projection, reconstructed, and segmented images) from a sintered glass beads column packing with enzymatically induced carbonate precipitation. The prepared sintered glass beads column sample has a dia... |
Jul 12, 2022 - Publication: Enzymatically induced carbonate precipitation
Ruf, Matthias; Hommel, Johannes; Steeb, Holger, 2022, "Enzymatically induced carbonate precipitation and its effect on capillary pressure-saturation relations of porous media - micro-XRCT dataset of high column (sample 4)", https://doi.org/10.18419/darus-2907, DaRUS, V1, UNF:6:ZBzSpg62B7xn5d+OtyUilg== [fileUNF]
This dataset contains micro X-ray Computed Tomography (micro-XRCT) data sets (projection, reconstructed, and segmented images) from a sintered glass beads column packing with enzymatically induced carbonate precipitation. The prepared sintered glass beads column sample has a diam... |
Jul 11, 2022 - Publication: Enzymatically induced carbonate precipitation
Ruf, Matthias; Hommel, Johannes; Steeb, Holger, 2022, "Enzymatically induced carbonate precipitation and its effect on capillary pressure-saturation relations of porous media - micro-XRCT dataset of medium column (sample 3)", https://doi.org/10.18419/darus-2906, DaRUS, V1, UNF:6:jlP3pZtBY1BpGYRex5PnqA== [fileUNF]
This dataset contains a micro X-ray Computed Tomography (micro-XRCT) data set (projection, reconstructed, and segmented images) from a sintered glass beads column packing with enzymatically induced carbonate precipitation. The prepared sintered glass beads column sample has a dia... |
Jun 22, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of Carrara marble with artificially created crack network: fast cooling down from 600°C", https://doi.org/10.18419/darus-682, DaRUS, V1
micro-XRCT data set (projection and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following therm... |
Jun 22, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of an in-situ flow experiment with an X-ray transparent flow cell", https://doi.org/10.18419/darus-691, DaRUS, V1
Micro-XRCT data sets (projection and reconstructed images) of an in-situ experiment with an X-ray transparent flow cell. As a porous medium, a 3 mm cylindrical sandstone core from the County of Bentheim was investigated. The conceptual design of the cell was presented in Fusseis... |
Jun 22, 2020 - Publication: Crystalline rocks
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of Carrara marble with artificially created crack network: slow cooling down from 600°C", https://doi.org/10.18419/darus-754, DaRUS, V1
micro-XRCT data set (projections and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following ther... |
Mar 12, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of open-pored asphalt concrete", https://doi.org/10.18419/darus-639, DaRUS, V1
micro-XRCT data set (projection and reconstructed images) resulting from a region of interest scan (diameter 48.41 mm, height 35.46 mm) located in the center of an open-pored asphalt concrete core with 100 mm diameter and 50 mm length. |