Subject: Earth and Environmental Sciences
Author Name: Ruf, Matthias
Author Affiliation: University of Stuttgart, Institute of Applied Mechanics (CE)
Funding Information Identifier: EXC 2075 - 390740016
1 to 9 of 9 Results
Sep 6, 2023 - Publication: Development of stochastically reconstructed 3D porous media micromodels using additive manufacturing: numerical and experimental validation
Ruf, Matthias; Lee, Dongwon; Yiotis, Andreas; Steeb, Holger, 2023, "micro-XRCT datasets of stochastically reconstructed 3D porous media micromodels manufactured by additive manufacturing", https://doi.org/10.18419/darus-3243, DaRUS, V1
This dataset contains micro X-ray Computed Tomography (micro-XRCT) scan data sets (projection, reconstructed, and binarized images) of 3D porous media micromodels manufactured by additive manufacturing using the Material Jetting (MJ) method. The micromodel geometries were designe... |
Jul 12, 2022 - Publication: Enzymatically induced carbonate precipitation
Ruf, Matthias; Hommel, Johannes; Steeb, Holger, 2022, "Enzymatically induced carbonate precipitation and its effect on capillary pressure-saturation relations of porous media - micro-XRCT dataset of low column (sample 10)", https://doi.org/10.18419/darus-2908, DaRUS, V1, UNF:6:lD3UlWjZQRaGPURMuWejpw== [fileUNF]
This dataset contains a micro X-ray Computed Tomography (micro-XRCT) data set (projection, reconstructed, and segmented images) from a sintered glass beads column packing with enzymatically induced carbonate precipitation. The prepared sintered glass beads column sample has a dia... |
Jul 12, 2022 - Publication: Enzymatically induced carbonate precipitation
Ruf, Matthias; Hommel, Johannes; Steeb, Holger, 2022, "Enzymatically induced carbonate precipitation and its effect on capillary pressure-saturation relations of porous media - micro-XRCT dataset of high column (sample 4)", https://doi.org/10.18419/darus-2907, DaRUS, V1, UNF:6:ZBzSpg62B7xn5d+OtyUilg== [fileUNF]
This dataset contains micro X-ray Computed Tomography (micro-XRCT) data sets (projection, reconstructed, and segmented images) from a sintered glass beads column packing with enzymatically induced carbonate precipitation. The prepared sintered glass beads column sample has a diam... |
Jul 11, 2022 - Publication: Enzymatically induced carbonate precipitation
Ruf, Matthias; Hommel, Johannes; Steeb, Holger, 2022, "Enzymatically induced carbonate precipitation and its effect on capillary pressure-saturation relations of porous media - micro-XRCT dataset of medium column (sample 3)", https://doi.org/10.18419/darus-2906, DaRUS, V1, UNF:6:jlP3pZtBY1BpGYRex5PnqA== [fileUNF]
This dataset contains a micro X-ray Computed Tomography (micro-XRCT) data set (projection, reconstructed, and segmented images) from a sintered glass beads column packing with enzymatically induced carbonate precipitation. The prepared sintered glass beads column sample has a dia... |
Mar 11, 2021 - Publication: Experimental Methods and Imaging for Enzymatically Induced Calcite Precipitation in a microfluidic cell
Vahid Dastjerdi, Samaneh; Steeb, Holger; Ruf, Matthias; Lee, Dongwon; Weinhardt, Felix; Karadimitriou, Nikolaos; Class, Holger, 2021, "micro-XRCT dataset of Enzymatically Induced Calcite Precipitation (EICP) in a microfluidic cell", https://doi.org/10.18419/darus-866, DaRUS, V1
micro-XRCT dataset (projection and reconstructed images) based on a region of interest scan (diameter 12.49 mm, height 9.09 mm) of a microfluidic cell including calcium carbonate aggregates along with the processed dataset (cropped, transformed and binarized). |
Jun 22, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of Carrara marble with artificially created crack network: fast cooling down from 600°C", https://doi.org/10.18419/darus-682, DaRUS, V1
micro-XRCT data set (projection and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following therm... |
Jun 22, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of an in-situ flow experiment with an X-ray transparent flow cell", https://doi.org/10.18419/darus-691, DaRUS, V1
Micro-XRCT data sets (projection and reconstructed images) of an in-situ experiment with an X-ray transparent flow cell. As a porous medium, a 3 mm cylindrical sandstone core from the County of Bentheim was investigated. The conceptual design of the cell was presented in Fusseis... |
Jun 22, 2020 - Publication: Crystalline rocks
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of Carrara marble with artificially created crack network: slow cooling down from 600°C", https://doi.org/10.18419/darus-754, DaRUS, V1
micro-XRCT data set (projections and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following ther... |
Mar 5, 2020 - Publication: Digital rock physics and laboratory considerations on a high-porosity volcanic rock
Schepp, Laura L.; Ahrens, Benedikt; Balcewicz, Martin; Duda, Mandy; Nehler, Mathias; Osorno, Maria; Uribe, David; Steeb, Holger; Nigon, Benoit; Stöckhert, Ferdinand; Swanson, Donald A.; Siegert, Mirko; Gurris, Marcel; Saenger, Erik H.; Ruf, Matthias, 2020, "Digital rock physics and laboratory considerations on a high-porosity volcanic rock: micro-XRCT data sets", https://doi.org/10.18419/darus-680, DaRUS, V1
Reticulite (high-porosity volcanic rock) is a pyroclastic rock formed during intense Hawaiian fountaining events. The honeycombed network of bubbles is supported by glassy threads and forms a structure with a porosity of more than 80 %. It is an end-member for high-porosity mater... |