Funding Information Identifier: STE 969/13-1
Subject: Computer and Information Science
Funding Information Agency: DFG
1 to 5 of 5 Results
Sep 26, 2022 - Publication: Particulate systems
Ruf, Matthias; Taghizadeh, Kianoosh; Steeb, Holger, 2021, "micro-XRCT data sets and in situ measured ultrasonic wave propagation of a pre-stressed monodisperse rubber and glass particle mixture with 50% volume rubber content", https://doi.org/10.18419/darus-2208, DaRUS, V2, UNF:6:Rf3VjhimtgZ3IVZt0sEaiw== [fileUNF]
This dataset contains two micro X-ray Computed Tomography (micro-XRCT) data sets from scans of the identical cylindrical sample (diameter 80 mm; unloaded height 80 mm) under different uniaxial compression loads. The sample consists of monodisperse soft (rubber) and stiff (glass)... |
Sep 26, 2022 - Publication: Particulate systems
Ruf, Matthias; Taghizadeh, Kianoosh; Steeb, Holger, 2022, "micro-XRCT data sets and in situ measured ultrasonic wave propagation of a pre-stressed monodisperse rubber and glass particle mixture with 30% volume rubber content", https://doi.org/10.18419/darus-2833, DaRUS, V1, UNF:6:V7YRRp377HBaXdVaRSc6ig== [fileUNF]
This dataset contains two micro X-ray Computed Tomography (micro-XRCT) data sets from scans of the identical cylindrical sample (diameter 80 mm; unloaded height 80 mm) under different uniaxial compression loads. The sample consists of monodisperse soft (rubber) and stiff (glass)... |
Jun 22, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of Carrara marble with artificially created crack network: fast cooling down from 600°C", https://doi.org/10.18419/darus-682, DaRUS, V1
micro-XRCT data set (projection and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following therm... |
Jun 22, 2020 - Publication: Crystalline rocks
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of Carrara marble with artificially created crack network: slow cooling down from 600°C", https://doi.org/10.18419/darus-754, DaRUS, V1
micro-XRCT data set (projections and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following ther... |
Mar 12, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of open-pored asphalt concrete", https://doi.org/10.18419/darus-639, DaRUS, V1
micro-XRCT data set (projection and reconstructed images) resulting from a region of interest scan (diameter 48.41 mm, height 35.46 mm) located in the center of an open-pored asphalt concrete core with 100 mm diameter and 50 mm length. |