1 to 10 of 20 Results
Aug 19, 2020Benchmarks
Contains numerical results related to the benchmark cases defined in the publication: I. Berre, W. Boon, B. Flemisch, A. Fumagalli, D. Gläser, E. Keilegavlen, A. Scotti, I. Stefansson, and A. Tatomir. Call for participation: Verification benchmarks for single-phase flow in three-... |
Jan 23, 2020
|
Jul 31, 2020 - Emmert2020a
Emmert, Simon; Class, Holger; Davis, Katherine; Gerlach, Robin, 2020, "Replication data for "Importance of Specific Substrate Utilization by Microbes in Microbially Enhanced Coal-Bed Methane Production: A Modelling Study"", https://doi.org/10.18419/darus-636, DaRUS, V1, UNF:6:etoZeSymT82caAlH+cVtVA== [fileUNF]
This contains the generated DuMuX model output (VTK files), extracted output (Python script) and plots (png) for the publication "Importance of Specific Substrate Utilization by Microbes in Microbially Enhanced Coal-Bed Methane Production: A Modelling Study" in International Jour... |
Mar 12, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of open-pored asphalt concrete", https://doi.org/10.18419/darus-639, DaRUS, V1
micro-XRCT data set (projection and reconstructed images) resulting from a region of interest scan (diameter 48.41 mm, height 35.46 mm) located in the center of an open-pored asphalt concrete core with 100 mm diameter and 50 mm length. |
Jun 22, 2020 - Publication: Crystalline rocks
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of Carrara marble with artificially created crack network: slow cooling down from 600°C", https://doi.org/10.18419/darus-754, DaRUS, V1
micro-XRCT data set (projections and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following ther... |
Jun 22, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of Carrara marble with artificially created crack network: fast cooling down from 600°C", https://doi.org/10.18419/darus-682, DaRUS, V1
micro-XRCT data set (projection and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following therm... |
Jun 22, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of an in-situ flow experiment with an X-ray transparent flow cell", https://doi.org/10.18419/darus-691, DaRUS, V1
Micro-XRCT data sets (projection and reconstructed images) of an in-situ experiment with an X-ray transparent flow cell. As a porous medium, a 3 mm cylindrical sandstone core from the County of Bentheim was investigated. The conceptual design of the cell was presented in Fusseis... |
Feb 13, 2020C-X1
Data for Emmert2020a publication: Importance of Specific Substrate Utilization by Microbes in Microbially Enhanced Coal-Bed Methane Production: A Modelling Study |