1 to 10 of 23 Results
Mar 30, 2021 - micro X-ray computed tomography data sets of human femoral heads
Ruf, Matthias; Steeb, Holger; Gebert, Johannes; Schneider, Ralf; Helwig, Peter, 2021, "Sample 1 of human femoral heads: micro-XRCT data sets", https://doi.org/10.18419/darus-1177, DaRUS, V1
Data contains micro X-Ray Computed Tomography (micro-XRCT) data sets of an explanted femoral head. This specimen was donated by a male patient at the age of 74 and a bodyweight of 128 kg who received a hip endoprosthesis. Additional information was not given. The explantation too... |
Sep 6, 2023 - Publication: Development of stochastically reconstructed 3D porous media micromodels using additive manufacturing: numerical and experimental validation
Ruf, Matthias; Lee, Dongwon; Yiotis, Andreas; Steeb, Holger, 2023, "micro-XRCT datasets of stochastically reconstructed 3D porous media micromodels manufactured by additive manufacturing", https://doi.org/10.18419/darus-3243, DaRUS, V1
This dataset contains micro X-ray Computed Tomography (micro-XRCT) scan data sets (projection, reconstructed, and binarized images) of 3D porous media micromodels manufactured by additive manufacturing using the Material Jetting (MJ) method. The micromodel geometries were designe... |
Sep 9, 2021 - Publication: Porosity and Permeability of Subflorescent Salt Crusts Formed by Evaporation From Porous Media
Ruf, Matthias; Lee, Dongwon; Piotrowski, Joseph; Huisman, Johan Alexander; Steeb, Holger, 2021, "micro-XRCT data sets of subflorescent salt crusts from evaporation of MgSO4 solution with 0.96 mol/L initial concentration", https://doi.org/10.18419/darus-2003, DaRUS, V1
This data set contains data of scans of three separated dry salt crusts that formed by evaporation of magnesium sulfate solution with 0.96 mol/L initial concentration from F32 quartz sand at 40%, 30%, and 25% saturation inside the sand packing. The cylindrical sample holder from... |
Sep 6, 2021 - Publication: Porosity and Permeability of Subflorescent Salt Crusts Formed by Evaporation From Porous Media
Ruf, Matthias; Lee, Dongwon; Piotrowski, Joseph; Huisman, Johan Alexander; Steeb, Holger, 2021, "micro-XRCT data sets of subflorescent salt crusts from evaporation of MgSO4 solution with 0.64 mol/L initial concentration", https://doi.org/10.18419/darus-1848, DaRUS, V1
This data set contains data of scans of three separated dry salt crusts that formed by evaporation of magnesium sulfate solution with 0.64 mol/L initial concentration from F32 quartz sand at 40%, 30%, and 20% saturation inside the sand packing. The cylindrical sample holder from... |
Sep 9, 2021 - Publication: Porosity and Permeability of Subflorescent Salt Crusts Formed by Evaporation From Porous Media
Ruf, Matthias; Lee, Dongwon; Piotrowski, Joseph; Huisman, Johan Alexander; Steeb, Holger, 2021, "micro-XRCT data sets of subflorescent salt crusts from evaporation of MgSO4 solution with 0.32 mol/L initial concentration", https://doi.org/10.18419/darus-2002, DaRUS, V1
This data set contains data of scans of three separated dry salt crusts that formed by evaporation of magnesium sulfate solution with 0.32 mol/L initial concentration from F32 quartz sand at 40%, 30%, and 20% saturation inside the sand packing. The cylindrical sample holder from... |
Jun 7, 2021 - Publication: Asphalt
Ruf, Matthias; Teutsch, Tim; Alber, Stefan; Steeb, Holger; Ressel, Wolfram, 2021, "micro-XRCT data sets of a stone mastic asphalt drill core before and after a uniaxial compression test (sample 2): sample 2-3", https://doi.org/10.18419/darus-1834, DaRUS, V1, UNF:6:QoLna7YlKfmQGxjSgS9yUA== [fileUNF]
This data set contains two micro X-ray Computed Tomography (micro-XRCT) data sets resulting from region of interest scans (diameter 58.32 mm, height 46.06 mm) of the center region of a stone mastic asphalt (SMA) drill core. The drill core was scanned with identical scanner settin... |
Jun 7, 2021 - Publication: Asphalt
Ruf, Matthias; Teutsch, Tim; Alber, Stefan; Steeb, Holger; Ressel, Wolfram, 2021, "micro-XRCT data sets of a stone mastic asphalt drill core before and after a uniaxial compression test (sample 2): sample 2-2", https://doi.org/10.18419/darus-1833, DaRUS, V1, UNF:6:mLc9Ef0BZefXh32Fhop7kw== [fileUNF]
This data set contains two micro X-ray Computed Tomography (micro-XRCT) data sets resulting from region of interest scans (diameter 58.32 mm, height 46.06 mm) of the center region of a stone mastic asphalt (SMA) drill core. The drill core was scanned with identical scanner settin... |
Jun 7, 2021 - Publication: Asphalt
Ruf, Matthias; Teutsch, Tim; Alber, Stefan; Steeb, Holger; Ressel, Wolfram, 2021, "micro-XRCT data sets of a stone mastic asphalt drill core before and after a uniaxial compression test (sample 2): sample 2-1", https://doi.org/10.18419/darus-1641, DaRUS, V2, UNF:6:mp7Zp2YBUbrj5d48PuMJ4w== [fileUNF]
This data set contains two micro X-ray Computed Tomography (micro-XRCT) data sets resulting from region of interest scans (diameter 58.32 mm, height 46.06 mm) of the center region of a stone mastic asphalt (SMA) drill core. The drill core was scanned with identical scanner settin... |
May 4, 2023 - Publication: Particulate systems
Ruf, Matthias; Taghizadeh, Kianoosh; Steeb, Holger, 2023, "micro-XRCT data sets and in situ measured ultrasonic wave propagation of pre-stressed monodisperse rubber and glass particle mixtures with 10%, 20%, and 30% volume rubber content: samples 2 and 3", https://doi.org/10.18419/darus-3437, DaRUS, V1, UNF:6:LyvQPm+lMHvJ9Z4neyxihA== [fileUNF]
This dataset contains 12 micro X-ray Computed Tomography (micro-XRCT) data sets from scans of cylindrical particulate mixture samples (diameter 80 mm; unloaded height 80 mm) under different uniaxial compression loads. The samples consist of monodisperse stiff (glass) and soft (ru... |
May 4, 2023 - Publication: Particulate systems
Ruf, Matthias; Taghizadeh, Kianoosh; Steeb, Holger, 2023, "micro-XRCT data sets and in situ measured ultrasonic wave propagation of pre-stressed monodisperse rubber and glass particle mixtures with 10%, 20%, 40%, and 60% volume rubber content: sample 1", https://doi.org/10.18419/darus-3436, DaRUS, V1, UNF:6:B6SNTx6Co9kvBdKrEWyCwA== [fileUNF]
This dataset contains 8 micro X-ray Computed Tomography (micro-XRCT) data sets from scans of cylindrical particulate mixture samples (diameter 80 mm; unloaded height 80 mm) under different uniaxial compression loads. The samples consist of monodisperse stiff (glass) and soft (rub... |