1 to 9 of 9 Results
Jul 29, 2021
Rees, Andreas; Oschwald, Michael, 2021, "Experimental data of flash boiling liquid nitrogen sprays (Test Case IN-1)", https://doi.org/10.18419/darus-2076, DaRUS, V1, UNF:6:WzjTONgKlTqgJ42vqQnX5g== [fileUNF]
The flash boiling process of superheated liquid nitrogen (LN2) under high-altitude conditions was investigated with the help of a cryogenic temperature adjustment system and injection system at the test bench M3.3 at DLR Lampoldshausen. The test fluid LN2 reaches its superheated... |
Adobe PDF - 1.2 MB -
MD5: 8e2926ff2474739f777d17d069893f1d
In this file some analysis examples in terms of diagrams of the measured raw-data are shown. |
Adobe PDF - 996.3 KB -
MD5: fed7186cbde6b12c5ad2e322d5089555
In this file theoretical background about flash boiling, a detailed description of the experimental set-up and the injection conditions can be found. Furthermore, the measured parameters, which are provided as raw-data, are explained. |
Tabular Data - 1.7 KB - 3 Variables, 91 Observations - UNF:6:11rgyBjOq9dSDaCT8fRRIg==
In this file arithmetic mean diameters D10 at the measured x/D and y/D distances to the injector are summarized. |
Tabular Data - 2.6 KB - 4 Variables, 91 Observations - UNF:6:AnEyp6KN50CDfd3O79wpTQ==
In this file arithmetic mean diameters D10 of the Hi- and Lo-droplet-populations at the measured x/D and y/D distances to the injector are summarized. |
Tabular Data - 2.7 KB - 4 Variables, 91 Observations - UNF:6:o/FM7wgyNUrfjGsUkjCc9Q==
In this file mean vertical velocity U values of the Hi- and Lo-droplet-populations at the measured x/D and y/D distances to the injector are summarized. |
MS Excel Spreadsheet - 26.1 KB -
MD5: 9251b13f9cffe445ca09553940f144bf
In this file all mean values of the measured parameters at different x/D and y/D distances to the injector are summarized. |
Tabular Data - 1.7 KB - 3 Variables, 91 Observations - UNF:6:2UlVU44YK37C29eM2SEPGA==
In this file mean vertical velocity U values at the measured x/D and y/D distances to the injector are summarized. |
Tabular Data - 1.7 KB - 3 Variables, 91 Observations - UNF:6:5KHiusCAf5HEQX+1lHxj9w==
In this file mean horizontal velocity V values at the measured x/D and y/D distances to the injector are summarized. |