This dataverse hosts all data aquired within the resreach project "qMOTION - Simulation-enhanced Highdensity Magneto-myographic Quantum Sensor Systems for Decoding Neuromuscular Control During Motion" funded by the European Reserach Council through ERC-AdG 2021 #101055186.

Abstract:
Being able to decode neural signals that control skeletal muscles with high accuracy will enable scientific breakthroughs in diagnostics and treatment, including early detection of neurodegenerative diseases, optimising personalised treatment or gene therapy, and assistive technologies like neuroprostheses. This breakthrough will require technology that is able to record signals from skeletal muscles in sufficient detail to allow the morpho-functional state of the neuromuscular system to be extracted. No existing technology can do this. Measuring the magnetic field induced by the flow of electrical charges in skeletal muscles, known as Magneto-myography (MMG), is expected to be the game-changing technology because magnetic fields are not attenuated by biological tissue. However, the extremely small magnetic fields involved require extremely sensitive magnetometers. The only promising option is novel quantum sensors, such as optically pumped magnetometers (OPMs), because they are small, modular, and can operate outside of specialised rooms. Our vision is to use this technology and our expertise in computational neuromechanics to decode, for the first time, neuromuscular control of skeletal muscles based on in vivo, high-density MMG data. For this purpose, we will design the first high-density MMG prototypes with up to 96 OPMs and develop custom calibration techniques. We will record magnetic fields induced by contracting skeletal muscles at the highest resolution ever measured. Such data, combined with the advanced computational musculoskeletal system models, will allow us to derive robust and reliable source localisation and separation algorithms. This will provide us with unique input for subject-specific neuromuscular models. We will demonstrate the superiority of the data over existing techniques with two applications; signs of ageing and neuromuscular disorders and show that it is possible to transfer these methodologies to clinical applications.
Featured Dataverses

In order to use this feature you must have at least one published or linked dataverse.

Publish Dataverse

Are you sure you want to publish your dataverse? Once you do so it must remain published.

Publish Dataverse

This dataverse cannot be published because the dataverse it is in has not been published.

Delete Dataverse

Are you sure you want to delete your dataverse? You cannot undelete this dataverse.

Advanced Search

41 to 50 of 88 Results
MATLAB Data - 123.6 MB - MD5: ef986621ea2d6202e690bfcb031f451a
Simulated high-density EMG and high-density MMG singal for a 30 second long voluntary isometric contraction.
MATLAB Data - 36.8 MB - MD5: 60e7e300f08d40dc9af223e37ee27f93
Simulated motor unit electric potentials (MUEPs) and motor unit magnetic fields (MUMFs) measured from a virtual high-density EMG or MMG array (70 sampling points).
MATLAB Data - 123.5 MB - MD5: c439ea9b47cf371ef4bef0cf69c0a131
Simulated high-density EMG and high-density MMG singal for a 30 second long voluntary isometric contraction.
MATLAB Data - 64.8 KB - MD5: f163915319fe40eda1a158b9f713d874
Motor unit territories for the simulated motor unit pools (Dim 1: y-coordinate, Dim 2: z-coordinate, Dim 3: Motor unit index).
MATLAB Data - 123.4 MB - MD5: 353fe512da62ff2e40b6347676c295e4
Simulated high-density EMG and high-density MMG singal for a 30 second long voluntary isometric contraction.
MATLAB Data - 123.6 MB - MD5: 57776e0d372ceed479bba1ab648d9ab3
Simulated high-density EMG and high-density MMG singal for a 30 second long voluntary isometric contraction.
MATLAB Data - 36.9 MB - MD5: a7a5f78ad4d238ceae46259db0933090
Simulated motor unit electric potentials (MUEPs) and motor unit magnetic fields (MUMFs) measured from a virtual high-density EMG or MMG array (70 sampling points).
MATLAB Data - 123.4 MB - MD5: 1b078d65522850de9ab75d6b20b0b469
Simulated high-density EMG and high-density MMG singal for a 30 second long voluntary isometric contraction.
MATLAB Data - 123.4 MB - MD5: 2aa19bdf52e1da85e95318f66d4fd270
Simulated high-density EMG and high-density MMG singal for a 30 second long voluntary isometric contraction.
MATLAB Data - 123.4 MB - MD5: 4f1ab3822924de6f3a12cd85a29f6c36
Simulated high-density EMG and high-density MMG singal for a 30 second long voluntary isometric contraction.
Add Data

Log in to create a dataverse or add a dataset.

Share Dataverse

Share this dataverse on your favorite social media networks.

Link Dataverse
Reset Modifications

Are you sure you want to reset the selected metadata fields? If you do this, any customizations (hidden, required, optional) you have done will no longer appear.