RP1-1: Co-design of functionally graded concrete building system.
RP1-2: Functionally graded concrete building system – design, optimisation, digital production and reuse.
Featured Dataverses

In order to use this feature you must have at least one published or linked dataverse.

Publish Dataverse

Are you sure you want to publish your dataverse? Once you do so it must remain published.

Publish Dataverse

This dataverse cannot be published because the dataverse it is in has not been published.

Delete Dataverse

Are you sure you want to delete your dataverse? You cannot undelete this dataverse.

Advanced Search

51 to 58 of 58 Results
PNG Image - 664.3 KB - MD5: 829c9d797dbf09162150a9c2db286c2f
Image with the observed crack pattern
Comma Separated Values - 7.8 KB - MD5: a4d1840cf63d938d4f2f8bd37f19a2dd
Values for the load-deformation curve of the numerical simulation used to perform the described mesh study
MS Excel Spreadsheet - 126.4 KB - MD5: cef56568e0a981040a4c60342431e5f4
Values for the load-deformation curve of the numerical simulation used to perform the described mesh study
Comma Separated Values - 25.5 KB - MD5: e6e05d4f209e4708e152ac63889170f4
Values for the load-deformation curve of the numerical simulation used to perform the described viscosity study
MS Excel Spreadsheet - 139.4 KB - MD5: 34737a48172d951a235490a8495f5050
Values for the load-deformation curve of the numerical simulation used to perform the described viscosity study
Oct 31, 2023
Teichmann, Alexander; Strahm, Benedikt; Garrecht, Harald; Blandini, Lucio, 2023, "Compressive strength measurement data of concrete samples", https://doi.org/10.18419/DARUS-3753, DaRUS, V1
Raw Data on the compressive strength measurements of concrete samples that have been evaluated as follows: The goal is to investigate the influence of different mixing approaches on the compressive strength of four distinct concrete mixtures. Compressive strength is a critical property that directly impacts the structural performance of concrete. T...
Comma Separated Values - 2.6 KB - MD5: 3e6b7b9519a72a5e9b573d5dc1454d82
Raw Data from Compressive Strength Measurements on cubes for 3 Test Series (0, S, Eco) and for 4 concrete mixtures (EM, SCC-L, SCC-F, HPC). CSV format: Values are separated by semicolon
MS Excel Spreadsheet - 14.3 KB - MD5: bd31507eb0ebf64ce5f88fb12d49ec17
Data
Raw Data from Compressive Strength Measurements on cubes for 3 Test Series (0, S, Eco) and for 4 concrete mixtures (EM, SCC-L, SCC-F, HPC)
Add Data

Log in to create a dataverse or add a dataset.

Share Dataverse

Share this dataverse on your favorite social media networks.

Link Dataverse
Reset Modifications

Are you sure you want to reset the selected metadata fields? If you do this, any customizations (hidden, required, optional) you have done will no longer appear.