Subarea B6(Universität Stuttgart)
Nov 5, 2021
Droplets under gradients of temperature and velocity by atomistic simulation
Oct 12, 2021
Schmidt, Johannes Benedikt; Hofmann, Julian; Tenzer, Fabian; Breitenbach, Jan; Tropea, Cameron; Roisman, Ilia, 2020, "Dataset: Thermosuperrepellency of a hot substrate caused by vapour percolation", https://doi.org/10.48328/TUDATALIB-530
The authors gratefully acknowledge the Deutsche Forschungsgemeinschaft for its financial support in the framework of the Collaborative Research Center SFB-TRR 75, project number 84292822 and the Industrieverband Massivumformung e.V..
This Dataset is harvested from our partners. Clicking the link will take you directly to the archival source of the data.
Jul 29, 2021 - Subarea B4
Rees, Andreas; Oschwald, Michael, 2021, "Experimental data of flash boiling liquid nitrogen sprays (Test Case IN-1)", https://doi.org/10.18419/DARUS-2076, DaRUS, V1, UNF:6:WzjTONgKlTqgJ42vqQnX5g== [fileUNF]
The flash boiling process of superheated liquid nitrogen (LN2) under high-altitude conditions was investigated with the help of a cryogenic temperature adjustment system and injection system at the test bench M3.3 at DLR Lampoldshausen. The test fluid LN2 reaches its superheated condition by varying the injection temperature or by a low-pressure en...
Adobe PDF - 1.2 MB - MD5: 8e2926ff2474739f777d17d069893f1d
In this file some analysis examples in terms of diagrams of the measured raw-data are shown.
Adobe PDF - 996.3 KB - MD5: fed7186cbde6b12c5ad2e322d5089555
In this file theoretical background about flash boiling, a detailed description of the experimental set-up and the injection conditions can be found. Furthermore, the measured parameters, which are provided as raw-data, are explained.
Tabular Data - 1.7 KB - 3 Variables, 91 Observations - UNF:6:11rgyBjOq9dSDaCT8fRRIg==
In this file arithmetic mean diameters D10 at the measured x/D and y/D distances to the injector are summarized.
Tabular Data - 2.6 KB - 4 Variables, 91 Observations - UNF:6:AnEyp6KN50CDfd3O79wpTQ==
In this file arithmetic mean diameters D10 of the Hi- and Lo-droplet-populations at the measured x/D and y/D distances to the injector are summarized.
Tabular Data - 2.7 KB - 4 Variables, 91 Observations - UNF:6:o/FM7wgyNUrfjGsUkjCc9Q==
In this file mean vertical velocity U values of the Hi- and Lo-droplet-populations at the measured x/D and y/D distances to the injector are summarized.
MS Excel Spreadsheet - 26.1 KB - MD5: 9251b13f9cffe445ca09553940f144bf
In this file all mean values of the measured parameters at different x/D and y/D distances to the injector are summarized.
Tabular Data - 1.7 KB - 3 Variables, 91 Observations - UNF:6:2UlVU44YK37C29eM2SEPGA==
In this file mean vertical velocity U values at the measured x/D and y/D distances to the injector are summarized.