This dataset contains ultrasound video recordings of the median nerve acquired using Superb Microvascular Imaging (SMI) in 12 healthy participants at different wrist positions. The data were analyzed for the publication
"Median Nerve Microvascularity Across Wrist Positions: A Superb Microvascular Imaging Study".
Abstract:
To quantify intraneural vascularity in healthy individuals using Superb Microvascular Imaging (SMI), implement a human-in-the-loop workflow, and characterize the vascular index (VI) across wrist positions and hand dominance.
Twelve healthy adults underwent bilateral 24-MHz longitudinal SMI of the median nerve at nine wrist positions from 40° extension to 40° flexion. The nerve was analyzed frame by frame using the Medical Segment Anything Model 2, and the color-coded pixels within the nerve mask were summarized as VI. Nonparametric repeated-measures analyses were conducted.
All 216 hand-position recordings were processed, and vascular signals were detected in every participant. Median VI ranged from 0.171% to 0.513% in the left hand and from 0.401% to 0.597% in the right hand. The global difference among the 18 hand-position combinations was not significant (χ²(17) = 24.33, p = 0.111; Kendall’s W = 0.119). Dominant and non-dominant hand summaries did not differ (Wilcoxon W = 53.0, p = 0.301).
SMI combined with promptable video segmentation enabled pixel-level quantification of intraneural vascular signals. In this small exploratory sample, no global differences were detected among hand-position combinations or between dominant- and non-dominant-hand summaries.
Instructions:
This data repository contains individual ultrasound video recordings of the median nerve acquired using SMI in 12 healthy participants. The recordings are provided as separate video files in DICOM format.
The individual files follow a standardized naming convention consisting of four components. For example, the filename 001smi0L can be interpreted as follows:
- The first three digits (e.g., 001) identify the participant number.
- smi indicates the ultrasound imaging modality (Superb Microvascular Imaging).
- The following digit (e.g., 0) indicates the wrist position.
- The final letter (L or R) indicates the examined side (left or right).
The dataset comprises 216 individual recordings, corresponding to 12 participants, two hands, and nine wrist positions per hand. The wrist positions range from 40° extension to 40° flexion.
How to obtain the data shown in the manuscript:
- The ultrasound video recordings used for the analysis presented in the manuscript can be accessed individually through this data repository.
- The recordings can be identified according to participant, imaging modality, wrist position, and examined side using the filename convention described above.
- The vascular index (VI) analysis described in the manuscript was performed frame by frame using the Medical Segment Anything Model 2 (MedSAM2), with the proportion of color-coded pixels within the segmented median nerve serving as the quantitative measure of intraneural vascularity.