This dataset comprises a time series of 12 micro-X-ray computed tomography (micro-XRCT) scans, capturing six distinct stages of the biomineralization process in a bio-concrete cylinder. Each measurement stage consists of two scans covering different sections of the specimen. Glass beads were added to the bio-concrete slurry to serve as reference markers for aligning the scans. Each dataset includes both the acquired projection images and the corresponding reconstructed cross-sectional images.
The specimen was prepared by Christoph Nething at the Institute for Lightweight Structures and Conceptual Design (ILEK), University of Stuttgart. The bacterial preparation was produced by Erik Eppinger at the Institute of Microbiology, University of Stuttgart.
The sand grain-size distribution, compaction procedure, and sample-holder design were based on the method described by Smirnova et al. (2023):
Smirnova, M., Nething, C., Stolz, A., et al. (2023). High strength bio-concrete for the production of building components.
npj Materials Sustainability, 1, 4.
https://doi.org/10.1038/s44296-023-00004-6
The sand was mixed with tap water and a urease-active bioslurry based on the approach described by Cheng and Shahin (2016):
Cheng, L., & Shahin, M. A. (2016). Urease active bioslurry: A novel soil improvement approach based on microbially induced carbonate precipitation.
Canadian Geotechnical Journal, 53(9), 1376–1385.
https://doi.org/10.1139/cgj-2015-0635
The initial mixture consisted of 91.6 wt.% sand, 3.7 wt.% bioslurry, and 4.7 wt.% tap water. The bioslurry had a water content of approximately 75%. The mixture was compacted into a cylindrical sample holder with an internal diameter of 52 mm and a height of 140 mm. The initial specimen porosity before biomineralization was approximately 0.30.
Biomineralization was induced through repeated bottom-to-top injections of a cementation solution containing 0.75 mol/L calcium chloride and 0.75 mol/L urea. A total of 24 injection cycles were performed, with each cycle lasting 4 h, corresponding to a nominal treatment duration of 96 h. The injection pressure and injected volume were maintained at 0.1 bar and 110 mL per cycle, respectively.
The specimen was scanned inside the sample holder before, during, and after the injection cycles. Because the field of view covered approximately half of the specimen height, two scans were acquired at every measurement stage. In the file names, the final number identifies the scanned section:
1 represents the upper section and
2 represents the lower section.
The in-holder time series extends from 4 h before the first injection to 90 h after the injection process began. The scans were acquired at the following stages:
Before biomineralization, −4 h relative to the start of the first injection:
20260616_02_BC_H_0_1 and
20260616_02_BC_H_0_2
After five injection cycles, 19 h:
20260617_01_BC_H_1_1 and
20260617_02_BC_H_1_2
After 11 injection cycles, 43 h:
20260618_01_BC_H_2_1 and
20260618_02_BC_H_2_2
After 17 injection cycles, 69 h:
20260619_01_BC_H_3_1 and
20260619_02_BC_H_3_2
After 24 injection cycles, 90 h:
20260622_01_BC_H_6_1 and
20260622_02_BC_H_6_2
A final pair of scans was acquired on 29 June 2026. Before these scans, the solidified specimen was removed from the sample holder and dried. The corresponding file names are:
20260629_01_BC_H_10_1 and
20260629_02_BC_H_10_2.
The micro-XRCT measurements were performed using the modular cone-beam micro-XRCT system at the Porous Media Laboratory (PML) of the Institute of Applied Mechanics, University of Stuttgart. The system consists of an X-ray source, a rotary specimen stage, and a flat-panel detector. A detailed description of the system is provided by Ruf and Steeb (2020):
Ruf, M., & Steeb, H. (2020). An open, modular, and flexible micro X-ray computed tomography system for research.
Review of Scientific Instruments, 91(11), 113102.
https://doi.org/10.1063/5.0019541
To obtain sufficient X-ray transmission through the specimen and sample holder, the scans were acquired using an X-ray tube voltage of 120 kV and a tube current of 100 µA. For each scan, 1,440 projection images were acquired over a full rotation, with an exposure time of 2,000 ms per projection. The geometric magnification resulted in an isotropic voxel size of approximately 33.97 µm.
The projection images were reconstructed at the Porous Media Laboratory using Octopus Reconstruction software 2019. Information about the software is available from the
archived Octopus Reconstruction website.