1 to 10 of 17 Results
Jun 7, 2021 - Publication: Asphalt
Ruf, Matthias; Teutsch, Tim; Alber, Stefan; Steeb, Holger; Ressel, Wolfram, 2021, "micro-XRCT data sets of a stone mastic asphalt drill core before and after a uniaxial compression test (sample 2): sample 2-1", https://doi.org/10.18419/darus-1641, DaRUS, V2, UNF:6:mp7Zp2YBUbrj5d48PuMJ4w== [fileUNF]
This data set contains two micro X-ray Computed Tomography (micro-XRCT) data sets resulting from region of interest scans (diameter 58.32 mm, height 46.06 mm) of the center region of a stone mastic asphalt (SMA) drill core. The drill core was scanned with identical scanner settin... |
Jun 7, 2021 - Publication: Asphalt
Ruf, Matthias; Teutsch, Tim; Alber, Stefan; Steeb, Holger; Ressel, Wolfram, 2021, "micro-XRCT data sets of a stone mastic asphalt drill core before and after a uniaxial compression test (sample 2): sample 2-2", https://doi.org/10.18419/darus-1833, DaRUS, V1, UNF:6:mLc9Ef0BZefXh32Fhop7kw== [fileUNF]
This data set contains two micro X-ray Computed Tomography (micro-XRCT) data sets resulting from region of interest scans (diameter 58.32 mm, height 46.06 mm) of the center region of a stone mastic asphalt (SMA) drill core. The drill core was scanned with identical scanner settin... |
Jun 7, 2021 - Publication: Asphalt
Ruf, Matthias; Teutsch, Tim; Alber, Stefan; Steeb, Holger; Ressel, Wolfram, 2021, "micro-XRCT data sets of a stone mastic asphalt drill core before and after a uniaxial compression test (sample 2): sample 2-3", https://doi.org/10.18419/darus-1834, DaRUS, V1, UNF:6:QoLna7YlKfmQGxjSgS9yUA== [fileUNF]
This data set contains two micro X-ray Computed Tomography (micro-XRCT) data sets resulting from region of interest scans (diameter 58.32 mm, height 46.06 mm) of the center region of a stone mastic asphalt (SMA) drill core. The drill core was scanned with identical scanner settin... |
Sep 6, 2021 - Publication: Porosity and Permeability of Subflorescent Salt Crusts Formed by Evaporation From Porous Media
Ruf, Matthias; Lee, Dongwon; Piotrowski, Joseph; Huisman, Johan Alexander; Steeb, Holger, 2021, "micro-XRCT data sets of subflorescent salt crusts from evaporation of MgSO4 solution with 0.64 mol/L initial concentration", https://doi.org/10.18419/darus-1848, DaRUS, V1
This data set contains data of scans of three separated dry salt crusts that formed by evaporation of magnesium sulfate solution with 0.64 mol/L initial concentration from F32 quartz sand at 40%, 30%, and 20% saturation inside the sand packing. The cylindrical sample holder from... |
Sep 9, 2021 - Publication: Porosity and Permeability of Subflorescent Salt Crusts Formed by Evaporation From Porous Media
Ruf, Matthias; Lee, Dongwon; Piotrowski, Joseph; Huisman, Johan Alexander; Steeb, Holger, 2021, "micro-XRCT data sets of subflorescent salt crusts from evaporation of MgSO4 solution with 0.32 mol/L initial concentration", https://doi.org/10.18419/darus-2002, DaRUS, V1
This data set contains data of scans of three separated dry salt crusts that formed by evaporation of magnesium sulfate solution with 0.32 mol/L initial concentration from F32 quartz sand at 40%, 30%, and 20% saturation inside the sand packing. The cylindrical sample holder from... |
Sep 9, 2021 - Publication: Porosity and Permeability of Subflorescent Salt Crusts Formed by Evaporation From Porous Media
Ruf, Matthias; Lee, Dongwon; Piotrowski, Joseph; Huisman, Johan Alexander; Steeb, Holger, 2021, "micro-XRCT data sets of subflorescent salt crusts from evaporation of MgSO4 solution with 0.96 mol/L initial concentration", https://doi.org/10.18419/darus-2003, DaRUS, V1
This data set contains data of scans of three separated dry salt crusts that formed by evaporation of magnesium sulfate solution with 0.96 mol/L initial concentration from F32 quartz sand at 40%, 30%, and 25% saturation inside the sand packing. The cylindrical sample holder from... |
Mar 14, 2022 - Publication: Effects of Thermal Treatment on Acoustic Waves in Carrara Marble
Ruf, Matthias; Steeb, Holger, 2021, "Effects of thermal treatment on acoustic waves in Carrara marble: measurement data", https://doi.org/10.18419/darus-1862, DaRUS, V2, UNF:6:yNzdCgAqR5WmMI9AAE0olA== [fileUNF]
This Dataset contains the measurement data of the related publication Ruf & Steeb (2022). In this, twelve thermal treatments, differing in the applied maximum temperature and the applied cooling condition (slow versus fast cooling) are experimentally studied for dry Bianco Carrar... |
Jul 11, 2022 - Publication: Enzymatically induced carbonate precipitation
Ruf, Matthias; Hommel, Johannes; Steeb, Holger, 2022, "Enzymatically induced carbonate precipitation and its effect on capillary pressure-saturation relations of porous media - micro-XRCT dataset of medium column (sample 3)", https://doi.org/10.18419/darus-2906, DaRUS, V1, UNF:6:jlP3pZtBY1BpGYRex5PnqA== [fileUNF]
This dataset contains a micro X-ray Computed Tomography (micro-XRCT) data set (projection, reconstructed, and segmented images) from a sintered glass beads column packing with enzymatically induced carbonate precipitation. The prepared sintered glass beads column sample has a dia... |
Jul 12, 2022 - Publication: Enzymatically induced carbonate precipitation
Ruf, Matthias; Hommel, Johannes; Steeb, Holger, 2022, "Enzymatically induced carbonate precipitation and its effect on capillary pressure-saturation relations of porous media - micro-XRCT dataset of high column (sample 4)", https://doi.org/10.18419/darus-2907, DaRUS, V1, UNF:6:ZBzSpg62B7xn5d+OtyUilg== [fileUNF]
This dataset contains micro X-ray Computed Tomography (micro-XRCT) data sets (projection, reconstructed, and segmented images) from a sintered glass beads column packing with enzymatically induced carbonate precipitation. The prepared sintered glass beads column sample has a diam... |
Jul 12, 2022 - Publication: Enzymatically induced carbonate precipitation
Ruf, Matthias; Hommel, Johannes; Steeb, Holger, 2022, "Enzymatically induced carbonate precipitation and its effect on capillary pressure-saturation relations of porous media - micro-XRCT dataset of low column (sample 10)", https://doi.org/10.18419/darus-2908, DaRUS, V1, UNF:6:lD3UlWjZQRaGPURMuWejpw== [fileUNF]
This dataset contains a micro X-ray Computed Tomography (micro-XRCT) data set (projection, reconstructed, and segmented images) from a sintered glass beads column packing with enzymatically induced carbonate precipitation. The prepared sintered glass beads column sample has a dia... |