451 to 460 of 585 Results
Mar 14, 2022 - Publication: Effects of Thermal Treatment on Acoustic Waves in Carrara Marble
Ruf, Matthias; Steeb, Holger, 2021, "Effects of thermal treatment on acoustic waves in Carrara marble: measurement data", https://doi.org/10.18419/DARUS-1862, DaRUS, V2, UNF:6:yNzdCgAqR5WmMI9AAE0olA== [fileUNF]
This Dataset contains the measurement data of the related publication Ruf & Steeb (2022). In this, twelve thermal treatments, differing in the applied maximum temperature and the applied cooling condition (slow versus fast cooling) are experimentally studied for dry Bianco Carrara marble under ambient conditions. Three sizes of cylindrical core sam... |
Gzip Archive - 987.2 MB -
MD5: 8fa87d92ab71ef894683e58a4cf8a3b7
Raw ultrasonic measurement data of the large samples in *.psdata and *.csv file format. File name schema: maximum applied temperature in degree Celsius; cooling protocol ("slow" or "fast"); measurement date ("t0" = before thermal treatment, "t1" = after thermal treatment); transducer type ("P-wave_1.0MHz" or "S-wave_1.0MHz"); optional: polar angle... |
Gzip Archive - 2.8 GB -
MD5: 207f8874db2dd6c60f56fa516e55d2e2
Raw ultrasonic measurement data of the medium samples in *.psdata and *.csv file format. File name schema: maximum applied temperature in degree Celsius; cooling protocol ("slow" or "fast"); measurement date ("t0" = before thermal treatment, "t1" = after thermal treatment); transducer type ("P-wave_1.0MHz" or "S-wave_1.0MHz"); optional: polar angle... |
Tabular Data - 15.9 KB - 35 Variables, 66 Observations - UNF:6:joJF3aozdn29i9JuMO+MQA==
Shear wave polar measurements for all samples in *.csv file format. Up to the reference samples, all measurements are related to the state after the thermal treatment was applied. The respective polar angle phi is specified in the header. E.g., "phi022.5deg" means a polar angle of phi = 22.5 deg. |
Tabular Data - 6.2 KB - 12 Variables, 66 Observations - UNF:6:vKEsnWStckpnsQZKJ/0FMw==
Measured and derived absolute quantities for all samples before ("t0") the thermal treatment was applied in *.csv file format. |
Tabular Data - 6.4 KB - 12 Variables, 66 Observations - UNF:6:q8dgOib7iAe43LWQnrhqAQ==
Measured and derived absolute quantities for all samples after ("t1") the respective thermal treatment was applied in *.csv file format. |
Tabular Data - 7.4 KB - 12 Variables, 66 Observations - UNF:6:BGT8Hv1L8ZJU4xWZJTT9Ig==
Relative change of the measured and derived quantities ("processed_data_absolute_values_t0.csv", "processed_data_absolute_values_t0.csv") for all samples due to the thermal treatment in *.csv file format. |
Gzip Archive - 1.4 GB -
MD5: 1cd77dc2fc37ebb7b6640dfc6c7f8747
Projection images (360 deg, angle increment 0.25 deg), dark image (di) and open beam image (ob) in 16 bit *.tif file format. Preload F_stat. = 400 N. |
Gzip Archive - 992.7 MB -
MD5: ce3904add33d71fdc31bab47d24b2000
Reconstructed micro-XRCT data set in 16 bit *.tif file format. 972x972x768 voxels with the uniform voxel size of 110 µm. Preload F_stat. = 400 N. |
Gzip Archive - 1.4 GB -
MD5: a6ebd773f66e49d4ef92499cb1bc7284
Projection images (360 deg, angle increment 0.25 deg), dark image (di) and open beam image (ob) in 16 bit *.tif file format. Preload F_stat. = 800 N. |