1 to 10 of 470 Results
Jul 29, 2024 - Publication: Foams
Ruf, Matthias; Steeb, Holger, 2024, "In situ micro-XRCT data set of an open-cell polyurethane foam sample under uniaxial compression load", https://doi.org/10.18419/darus-3010, DaRUS, V1, UNF:6:uDIvFcZaJFdGVoODn5h7UA== [fileUNF]
This dataset contains seven micro X-Ray Computed Tomography (micro-XRCT) scan data sets (projection, reconstructed, and segmented images, respectively) of an open-cell reticulated Polyurethane (PUR) foam specimen with 10 pores per inch under different uniaxial deformation states.... |
Jul 29, 2024 -
In situ micro-XRCT data set of an open-cell polyurethane foam sample under uniaxial compression load
Adobe PDF - 56.9 KB -
MD5: 988914e0382192fb5f909fb0ac8fbd81
Datasheet of the used Polyurethane Foam PPI 10. |
Jul 29, 2024 -
In situ micro-XRCT data set of an open-cell polyurethane foam sample under uniaxial compression load
Gzip Archive - 1.5 GB -
MD5: 391f9c331c8bcb3f6c4517dbd6946b3a
Projection images (360 deg, angle increment 0.25 deg), dark image (di) and open beam image (ob) in 16 bit *.tif file format. Uniaxial compression 0 mm. |
Jul 29, 2024 -
In situ micro-XRCT data set of an open-cell polyurethane foam sample under uniaxial compression load
Gzip Archive - 780.8 MB -
MD5: e250b1d79f2807fa668c7b5638b637f9
Reconstructed micro-XRCT data set of "t0_projections.tar.gz" in 16 bit *.tif file format. 972x972x711 voxel, uniform voxel size of 74.8 µm. Uniaxial compression 0 mm. |
Jul 29, 2024 -
In situ micro-XRCT data set of an open-cell polyurethane foam sample under uniaxial compression load
Gzip Archive - 5.7 MB -
MD5: 3aa1971ce8a6f934b4b28c089588aab5
Segmented images of "t0_reconstructed.tar.gz" into foam skeleton and void space in 8 bit *.tif file format. 751x751x593 voxels with a uniform voxel size of 74.8 µm. |
Jul 29, 2024 -
In situ micro-XRCT data set of an open-cell polyurethane foam sample under uniaxial compression load
Tabular Data - 74.5 KB - 4 Variables, 4559 Observations - UNF:6:UfBiCmb/bPKeu5fEiVQEZQ==
UTM data after reaching the target position (uniaxial compression 0 mm) during subsequent relaxation and image acquisition. |
Jul 29, 2024 -
In situ micro-XRCT data set of an open-cell polyurethane foam sample under uniaxial compression load
Gzip Archive - 1.5 GB -
MD5: 2ad66c65b7de8047b8986e9a9dcf1e62
Projection images (360 deg, angle increment 0.25 deg), dark image (di) and open beam image (ob) in 16 bit *.tif file format. Uniaxial compression 10 mm. |
Jul 29, 2024 -
In situ micro-XRCT data set of an open-cell polyurethane foam sample under uniaxial compression load
Gzip Archive - 802.3 MB -
MD5: 4ce78c6a1950d8d2c7ea95f20e1f581e
Reconstructed micro-XRCT data set of "t1_projections.tar.gz" in 16 bit *.tif file format. 972x972x711 voxel, uniform voxel size of 74.8 µm. Uniaxial compression 5 mm. |
Jul 29, 2024 -
In situ micro-XRCT data set of an open-cell polyurethane foam sample under uniaxial compression load
Gzip Archive - 5.4 MB -
MD5: d019359266d56da4dfdfcefd0929d0d7
Segmented images of "t1_reconstructed.tar.gz" into foam skeleton and void space in 8 bit *.tif file format. 751x751x530 voxels with a uniform voxel size of 74.8 µm. |
Jul 29, 2024 -
In situ micro-XRCT data set of an open-cell polyurethane foam sample under uniaxial compression load
Tabular Data - 69.3 KB - 4 Variables, 3794 Observations - UNF:6:vhSJDaGNn0pYNmW/w6bK1w==
UTM data after reaching the target position (uniaxial compression 5 mm) during subsequent relaxation and image acquisition. |