171 to 180 of 276 Results
May 30, 2022 - Structural Dynamics
Müller, Florian, 2022, "Self-adaptive beam slider system - experimental results", https://doi.org/10.18419/DARUS-2883, DaRUS, V1
This datasets contains experimental data that was recorded during experiments with our self-adaptive beam-slider system. Under external harmonic excitation, this system has the capability to passively adjust its dynamics such that a very large vibration level is achieved and maintained in a broad range of operating conditions. Measured quantities a... |
May 20, 2022 - SFB-TRR 161 INF "Collaboration Infrastructure"
Garkov, Dimitar; Müller, Christoph; Klein, Karsten; Ertl, Thomas; Schreiber, Falk; Task-Force A, 2022, "Guidelines on Replication and Research Data Management", https://doi.org/10.18419/DARUS-2843, DaRUS, V1
This document summarises guidelines for reproducibility in SFB/Transregio 161 by Task Force A (TF-A). It builds upon the data management plan (version 1.0, 2020, https://doi.org/10.18419/darus-632) and focusses on three main points: Provide clear definitions of reproducibility and replicability in the context of TF-A. Coordinate efforts on research... |
May 18, 2022 - Biophysics Group
Wang, Shuo; Findeisen, Lukas; Leptihn, Sebastian; Wallace, Mark Ian; Hörning, Marcel; Nussberger, Stephan, 2022, "Data for: Correlation of mitochondrial TOM core complex stop-and-go and open-closed channel dynamics", https://doi.org/10.18419/DARUS-2158, DaRUS, V1, UNF:6:9dvSdn6uEaqFUk/rRvtwoA== [fileUNF]
The role of lateral diffusion of proteins in the membrane in the context of function has not been examined extensively. The data set addresses the relationship between protein lateral diffusion and channel activity of the general protein import pore of mitochondria (TOM-CC). Optical ion flux sensing through single TOM-CC molecules shows that TOM-CC... |
May 17, 2022 - AG_BioMat
Daul, Anna; Lemloh, Marie-Louise; Hörning, Marcel, 2022, "Data for: Galvanotaxis of ciliates: Spatiotemporal dynamics of Coleps hirtus under electric fields", https://doi.org/10.18419/DARUS-2827, DaRUS, V1
Time-lapse records observed with a stereo microscope (Stemi 508, Zeiss, Carl Zeiss Microscopy GmbH) equipped with a camera (Axiocam 503, Zeiss, Carl Zeiss Microscopy GmbH). Spatial magnification is set to 20.475× by using a 0.65× zoom, a 63× objective lens and a 0.5× wide angle camera adapter. Time-series were taken by using the ZEN software (ZEN 2... |
May 16, 2022PN 4
Combining First Principles and Neural Network Models for Interpretable, High-Precision Multi-Step Predictions (InMotion) |
May 13, 2022 - Institut für Strahlwerkzeuge
Faure, Frauke; Hagenlocher, Christian; Lind, Jannik; Wagner, Jonas; Weber, Rudolf; Graf, Thomas, 2022, "10 kHz x-ray video of laser beam welding of copper", https://doi.org/10.18419/DARUS-2086, DaRUS, V1
At the X-ray facility at the IFSW, so far it has been possible to record videos with a framerate of 1 kHz to 3 kHz. In this setup the X-rays propagate through the workpiece and are filmed by the high-speed camera via a projection on the scintilator. Through a new sample formation and using less attenuating sample material, frame rates of 10 kHz cou... |