1 to 10 of 15 Results
Feb 15, 2021 - Data Analytics in Engineering
Lißner, Julian, 2020, "2d microstructure data", https://doi.org/10.18419/darus-1151, DaRUS, V2
The hdf5 file contains image data of inclusion based microstructured material and the homogenized effective heat conductivity thereof. The microstructure is defined with a representative volume element with periodic boundary conditions. 30.000 images are contained and split into... |
Dec 15, 2020 - Publications
Tapia Camú, Cristóbal; Aicher, Simon, 2020, "Replication Data for: Simulation of the localized modulus of elasticity of hardwood boards by means of an autoregressive model", https://doi.org/10.18419/darus-863, DaRUS, V2, UNF:6:3jJ2Tj1s/C8WfiVWORPRtw== [fileUNF]
This repository contains the global and localized data gathered for a set of 52 oak boards with a cross-section of 175 x 24 mm. Modulus of elasticity, density and knot information were recorded. |
Jul 31, 2020 - Emmert2020a
Emmert, Simon; Class, Holger; Davis, Katherine; Gerlach, Robin, 2020, "Replication data for "Importance of Specific Substrate Utilization by Microbes in Microbially Enhanced Coal-Bed Methane Production: A Modelling Study"", https://doi.org/10.18419/darus-636, DaRUS, V1, UNF:6:etoZeSymT82caAlH+cVtVA== [fileUNF]
This contains the generated DuMuX model output (VTK files), extracted output (Python script) and plots (png) for the publication "Importance of Specific Substrate Utilization by Microbes in Microbially Enhanced Coal-Bed Methane Production: A Modelling Study" in International Jour... |
Jun 22, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of Carrara marble with artificially created crack network: fast cooling down from 600°C", https://doi.org/10.18419/darus-682, DaRUS, V1
micro-XRCT data set (projection and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following therm... |
Jun 22, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of an in-situ flow experiment with an X-ray transparent flow cell", https://doi.org/10.18419/darus-691, DaRUS, V1
Micro-XRCT data sets (projection and reconstructed images) of an in-situ experiment with an X-ray transparent flow cell. As a porous medium, a 3 mm cylindrical sandstone core from the County of Bentheim was investigated. The conceptual design of the cell was presented in Fusseis... |
Jun 22, 2020 - Publication: Crystalline rocks
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of Carrara marble with artificially created crack network: slow cooling down from 600°C", https://doi.org/10.18419/darus-754, DaRUS, V1
micro-XRCT data set (projections and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following ther... |
Jun 16, 2020 - EICPModelCalibration
Hommel, Johannes, 2020, "EICP Model Calibration", https://doi.org/10.18419/darus-796, DaRUS, V1
EICP Model Calibration. Content: 1 excel spreadsheet with the experimental data 4 different model calibration sets in each .tar file: SorptionCoefficientsOnlyFitted.tar for the case where only the sorption coefficients of urease are fitted. SorptionCoefficientsAndConcentrationsFi... |
May 27, 2020 - Dennis Zink
Zink, Dennis, 2020, "Results and raw data of an adjustable similarity calculation for computer aided design (CAD) data", https://doi.org/10.18419/darus-813, DaRUS, V1
The here shown data results from a methodology for calculating the similarity of CAD parts. CAD parts are analyzed using various algorithms to find geometric features and discrete point cloud representations. The folder AnalyzedCADData contains a zip-file with the raw analyzed da... |
Mar 12, 2020 - Publication: An open, modular, and flexible micro X-ray computed tomography system for research
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of open-pored asphalt concrete", https://doi.org/10.18419/darus-639, DaRUS, V1
micro-XRCT data set (projection and reconstructed images) resulting from a region of interest scan (diameter 48.41 mm, height 35.46 mm) located in the center of an open-pored asphalt concrete core with 100 mm diameter and 50 mm length. |
Mar 5, 2020 - Publication: Digital rock physics and laboratory considerations on a high-porosity volcanic rock
Schepp, Laura L.; Ahrens, Benedikt; Balcewicz, Martin; Duda, Mandy; Nehler, Mathias; Osorno, Maria; Uribe, David; Steeb, Holger; Nigon, Benoit; Stöckhert, Ferdinand; Swanson, Donald A.; Siegert, Mirko; Gurris, Marcel; Saenger, Erik H.; Ruf, Matthias, 2020, "Digital rock physics and laboratory considerations on a high-porosity volcanic rock: micro-XRCT data sets", https://doi.org/10.18419/darus-680, DaRUS, V1
Reticulite (high-porosity volcanic rock) is a pyroclastic rock formed during intense Hawaiian fountaining events. The honeycombed network of bubbles is supported by glassy threads and forms a structure with a porosity of more than 80 %. It is an end-member for high-porosity mater... |