371 to 380 of 510 Results
Plain Text - 3.3 KB -
MD5: a716807308261f30df00f4ab500b3877
Readme file |
May 10, 2022 -
Replication Data for: Diamond magnetometry and gradiometry towards subpicotesla DC field measurement
MATLAB Source Code - 1.5 KB -
MD5: 3676a386e8131d4aba2a4f084cb9ff11
The codes calculate the theoretical sensitivity with different laser and MW power. The calculated variable 'sensitivity_log' is used for the plotting of Fig3a. The codes are written in m file for matlab. It can also be reproduced for other languages. |
May 10, 2022 -
Replication Data for: Diamond magnetometry and gradiometry towards subpicotesla DC field measurement
Tabular Data - 4.0 MB - 803 Variables, 402 Observations - UNF:6:m5xpIpWyT8gUmMk742gNBQ==
csv file for 'fig3a.xlsx' |
May 10, 2022 -
Replication Data for: Diamond magnetometry and gradiometry towards subpicotesla DC field measurement
MS Excel Spreadsheet - 4.0 MB -
MD5: 0d39c089afe71b2d50e16e30bdb1212d
Row 1 from C is the optical saturation parameter;
Column A from A3 is the Rabi frequency in Hz;
The table from C3 to ADW403 is the logarithmic sensitivity. |
May 10, 2022 -
Replication Data for: Diamond magnetometry and gradiometry towards subpicotesla DC field measurement
Tabular Data - 273.4 KB - 6 Variables, 4999 Observations - UNF:6:AySfJzAzcL0TXc8/dkT+Pw==
csv file for 'Fig3b.xlsx' |
May 10, 2022 -
Replication Data for: Diamond magnetometry and gradiometry towards subpicotesla DC field measurement
MS Excel Spreadsheet - 311.9 KB -
MD5: 73cf6356df1bd710de31cec92d7fa61e
Column A: time tags of the experimental data;
Column B: measured fluorescence signal (normalized);
Column C: time tags for the simulation;
Column D-F: Simulated signal
In the legends: k is the pumping rate, and T1 is the longitude decoherence time (see controlled variables)
Laser power is at 80 mW. |
May 10, 2022 -
Replication Data for: Diamond magnetometry and gradiometry towards subpicotesla DC field measurement
Tabular Data - 1.4 KB - 5 Variables, 25 Observations - UNF:6:v//6NaoHwB3sIzLBDQkclA==
csv file for 'Fig3c.xlsx' |
May 10, 2022 -
Replication Data for: Diamond magnetometry and gradiometry towards subpicotesla DC field measurement
MS Excel Spreadsheet - 9.8 KB -
MD5: 4e524a9d9afdb764bd02819ab296e8b4
Column A: Rabi frequency (MHz);
Column B-D: Experimental data (3 times);
Column E: fitting |
May 10, 2022 -
Replication Data for: Diamond magnetometry and gradiometry towards subpicotesla DC field measurement
Tabular Data - 495 B - 4 Variables, 15 Observations - UNF:6:6JPgX8ZBc7wUUNDRdPlodw==
csv file for 'Fig3d.xlsx' |
May 10, 2022 -
Replication Data for: Diamond magnetometry and gradiometry towards subpicotesla DC field measurement
MS Excel Spreadsheet - 8.7 KB -
MD5: 1fc6ac6ee5bdb48eeabd953c2767ad11
Column A: Modulation frequency (Hz);
Column B-D: simulated fluorescence signal contrast.
In the legends: k is the pumping rate, and T1 is the longitude decoherence time (see controlled variables)
Laser power is at 80 mW. |