{"id":4394,"identifier":"darus-818","persistentUrl":"https://doi.org/10.18419/darus-818","protocol":"doi","authority":"10.18419","publisher":"DaRUS","publicationDate":"2021-02-10","storageIdentifier":"s3://10.18419/darus-818","datasetVersion":{"id":394,"datasetId":4394,"datasetPersistentId":"doi:10.18419/darus-818","storageIdentifier":"s3://10.18419/darus-818","versionNumber":1,"versionMinorNumber":0,"versionState":"RELEASED","lastUpdateTime":"2022-11-09T14:42:59Z","releaseTime":"2021-02-10T08:41:18Z","createTime":"2020-07-21T11:45:25Z","publicationDate":"2021-02-10","citationDate":"2021-02-10","license":{"name":"CC BY 4.0","uri":"http://creativecommons.org/licenses/by/4.0","iconUri":"https://licensebuttons.net/l/by/4.0/88x31.png"},"fileAccessRequest":false,"metadataBlocks":{"citation":{"displayName":"Citation Metadata","name":"citation","fields":[{"typeName":"title","multiple":false,"typeClass":"primitive","value":"Optical Microscopy and pressure measurements of Enzymatically Induced Calcite Precipitation (EICP) in a microfluidic cell"},{"typeName":"author","multiple":true,"typeClass":"compound","value":[{"authorName":{"typeName":"authorName","multiple":false,"typeClass":"primitive","value":"Weinhardt, Felix"},"authorAffiliation":{"typeName":"authorAffiliation","multiple":false,"typeClass":"primitive","value":"University of Stuttgart, Institute for Modelling Hydraulic and Environmental Systems (IWS)"},"authorIdentifierScheme":{"typeName":"authorIdentifierScheme","multiple":false,"typeClass":"controlledVocabulary","value":"ORCID"},"authorIdentifier":{"typeName":"authorIdentifier","multiple":false,"typeClass":"primitive","value":"0000-0002-1758-9427"}},{"authorName":{"typeName":"authorName","multiple":false,"typeClass":"primitive","value":"Class, Holger"},"authorAffiliation":{"typeName":"authorAffiliation","multiple":false,"typeClass":"primitive","value":"University of Stuttgart, Institute for Modelling Hydraulic and Environmental Systems (IWS)"},"authorIdentifierScheme":{"typeName":"authorIdentifierScheme","multiple":false,"typeClass":"controlledVocabulary","value":"ORCID"},"authorIdentifier":{"typeName":"authorIdentifier","multiple":false,"typeClass":"primitive","value":"0000-0002-4476-8017"}},{"authorName":{"typeName":"authorName","multiple":false,"typeClass":"primitive","value":"Vahid Dastjerdi, Samaneh"},"authorAffiliation":{"typeName":"authorAffiliation","multiple":false,"typeClass":"primitive","value":"University of Stuttgart, Institute of Applied Mechanics (CE)"},"authorIdentifierScheme":{"typeName":"authorIdentifierScheme","multiple":false,"typeClass":"controlledVocabulary","value":"ORCID"},"authorIdentifier":{"typeName":"authorIdentifier","multiple":false,"typeClass":"primitive","value":"0000-0003-0315-4067"}},{"authorName":{"typeName":"authorName","multiple":false,"typeClass":"primitive","value":"Karadimitriou, Nikolaos"},"authorAffiliation":{"typeName":"authorAffiliation","multiple":false,"typeClass":"primitive","value":"University of Stuttgart, Institute of Applied Mechanics (CE)"},"authorIdentifierScheme":{"typeName":"authorIdentifierScheme","multiple":false,"typeClass":"controlledVocabulary","value":"ORCID"},"authorIdentifier":{"typeName":"authorIdentifier","multiple":false,"typeClass":"primitive","value":"0000-0002-9461-6214"}},{"authorName":{"typeName":"authorName","multiple":false,"typeClass":"primitive","value":"Lee, Dongwon"},"authorAffiliation":{"typeName":"authorAffiliation","multiple":false,"typeClass":"primitive","value":"University of Stuttgart, Institute of Applied Mechanics (CE)"},"authorIdentifierScheme":{"typeName":"authorIdentifierScheme","multiple":false,"typeClass":"controlledVocabulary","value":"ORCID"},"authorIdentifier":{"typeName":"authorIdentifier","multiple":false,"typeClass":"primitive","value":"0000-0002-5359-7803"}},{"authorName":{"typeName":"authorName","multiple":false,"typeClass":"primitive","value":"Steeb, Holger"},"authorAffiliation":{"typeName":"authorAffiliation","multiple":false,"typeClass":"primitive","value":"University of Stuttgart, Institute of Applied Mechanics (CE) & SimTech"},"authorIdentifierScheme":{"typeName":"authorIdentifierScheme","multiple":false,"typeClass":"controlledVocabulary","value":"ORCID"},"authorIdentifier":{"typeName":"authorIdentifier","multiple":false,"typeClass":"primitive","value":"0000-0001-7602-4920"}}]},{"typeName":"datasetContact","multiple":true,"typeClass":"compound","value":[{"datasetContactName":{"typeName":"datasetContactName","multiple":false,"typeClass":"primitive","value":"Weinhardt, Felix"},"datasetContactAffiliation":{"typeName":"datasetContactAffiliation","multiple":false,"typeClass":"primitive","value":"University of Stuttgart, Institute for Modelling Hydraulic and Environmental Systems (IWS)"}},{"datasetContactName":{"typeName":"datasetContactName","multiple":false,"typeClass":"primitive","value":"Steeb, Holger"},"datasetContactAffiliation":{"typeName":"datasetContactAffiliation","multiple":false,"typeClass":"primitive","value":"University of Stuttgart, Institute of Applied Mechanics (CE) & SimTech"}}]},{"typeName":"dsDescription","multiple":true,"typeClass":"compound","value":[{"dsDescriptionValue":{"typeName":"dsDescriptionValue","multiple":false,"typeClass":"primitive","value":"Content: \n
\nThis dataset includes raw as well as processed data from three experiments (Exp 1 - 3). Each dataset consists of the readouts from the pressure sensor(s), as logged with the use of QmixElements, raw images, and segmented images.\n
\n
\nLog files: \n
\nData in the log files are essentially the raw output of the software QMixElements which is used to operate the syringe pumps and log the pressure sensors. It consists of the columns time, inlet pressure, outlet pressure as well as the flow rates of the two syringes. We need to point out that each pressure sensor has an offset which needs to be accounted for in order to account for the actual pressure in the most accurate way. In order to derive the correct pressure drop (Δp) across the flow cell (outlet pressure - inlet pressure), a two minute period of no flow is applied. It is expected that in the absence of flow the pressure drop across the cell has to be zero and, therefore, the offset of the pressure drop can be determined.\nFor each experiment there are separate log files for \n