Sample 1 of human femoral heads: micro-XRCT data setsdoi:10.18419/darus-1177DaRUS2021-03-301Ruf, Matthias; Steeb, Holger; Gebert, Johannes; Schneider, Ralf; Helwig, Peter, 2021, "Sample 1 of human femoral heads: micro-XRCT data sets", https://doi.org/10.18419/darus-1177, DaRUS, V1Sample 1 of human femoral heads: micro-XRCT data setsdoi:10.18419/darus-1177Ruf, MatthiasSteeb, HolgerGebert, JohannesSchneider, RalfHelwig, PeterRuf, MatthiasSteeb, HolgerUniversity of Stuttgart, Institute of Applied Mechanics (CE) - Chair for Continuum-MechanicsUniversity of Stuttgart - SC SimTech2020-11-25University of Stuttgart, Institute of Applied Mechanics (CE)DaRUSSteeb, HolgerSchneider, RalfComputer and Information ScienceEngineeringMedicine, Health and Life SciencesHuman femoral headmicro X-ray Computed Tomography (micro-XRCT)High Performance Computing (HPC)Data contains micro X-Ray Computed Tomography (micro-XRCT) data sets of an explanted femoral head. This specimen was donated by a male patient at the age of 74 and a bodyweight of 128 kg who received a hip endoprosthesis. Additional information was not given. The explantation took place in cooperation with Prof. Dr. Peter Helwig at the Clinic Heidenheim, southern Germany.<br>
<br>
The human femoral head was unfrozen before performing the micro-XRCT scans.
We acquired three micro-XRCT data sets with two different geometric magnifications (resolutions). The data set "reconstructed_20201125_01.rar" is an overview scan of almost the entire human femoral head. The data sets "reconstructed_20201126_01.rar" and "reconstructed_20201127_01.rar" provide a detailed view of the center region. "reconstructed_20201126_01.rar" shows the lower part and "reconstructed_20201127_01.rar" the upper part of "reconstructed_20201125_01.rar".Image dataGebert, J., Schneider, R., Helwig, P., & Schenkengel, J.-P. (2021). HLRS_Helwig_2020_Hueftkopf_01_B40f: A clinical computed tomography scan of a human femoral head. DaRUS. <a href="https://doi.org/10.18419/DARUS-1182">https://doi.org/10.18419/DARUS-1182</a>Ruf, M., & Steeb, H. (2020). An open, modular, and flexible micro X-ray computed tomography system for research. <em>Review of Scientific Instruments</em>, 91(11), 113102. <a href="https://doi.org/10.1063/5.0019541">https://doi.org/10.1063/5.0019541</a>reconstructed_20201125_01.rarReconstructed micro-XRCT data set in 16 bit *.tif file format. 2940x2940x2141 voxels with the uniform voxel size of 15.0 µm. Overview scan.application/x-rar-compressedreconstructed_20201126_01.rarReconstructed micro-XRCT data set in 16 bit *.tif file format. 2940x2940x2141 voxels with the uniform voxel size of 5.0 µm. Lower part scan.application/x-rar-compressedreconstructed_20201127_01.rarReconstructed micro-XRCT data set in 16 bit *.tif file format. 2940x2940x2141 voxels with the uniform voxel size of 5.0 µm. Upper part scan.application/x-rar-compressed