View: |
Part 1: Document Description
|
Citation |
|
---|---|
Title: |
Dynamic CT imaging of bone cement injection through aluminium foam |
Identification Number: |
doi:10.18419/darus-2037 |
Distributor: |
DaRUS |
Date of Distribution: |
2021-06-23 |
Version: |
1 |
Bibliographic Citation: |
Trivedi, Zubin, 2021, "Dynamic CT imaging of bone cement injection through aluminium foam", https://doi.org/10.18419/darus-2037, DaRUS, V1, UNF:6:H7VS7vaCTD5/iVSCIXdACQ== [fileUNF] |
Citation |
|
Title: |
Dynamic CT imaging of bone cement injection through aluminium foam |
Identification Number: |
doi:10.18419/darus-2037 |
Authoring Entity: |
Trivedi, Zubin (Universität Stuttgart) |
Other identifications and acknowledgements: |
Gehweiler, Dominic |
Other identifications and acknowledgements: |
AO Research Institute, Davos |
Other identifications and acknowledgements: |
Röhrle, Oliver |
Other identifications and acknowledgements: |
Wagner, Arndt |
Other identifications and acknowledgements: |
Ricken, Tim |
Other identifications and acknowledgements: |
Gueorguiev-Rüegg, Boyko |
Other identifications and acknowledgements: |
SFB 1313 |
Distributor: |
DaRUS |
Access Authority: |
Trivedi, Zubin |
Access Authority: |
Röhrle, Oliver |
Depositor: |
Trivedi, Zubin |
Date of Deposit: |
2021-06-21 |
Holdings Information: |
https://doi.org/10.18419/darus-2037 |
Study Scope |
|
Keywords: |
Engineering, Medicine, Health and Life Sciences, Vertebroplasty, Bone cements, Computed tomography |
Abstract: |
The process of vertebroplasty is experimentally simulated by injecting a commercially available bone cement (rheology previously characterised) into a piece of aluminium foam (diameter 40 mm) with pore structure similar to that of cancellous bone inside a vertebra. The cement infiltration pattern is captured using a dynamic CT imaging setup. The bone cement is injected with a flow rate of 0.4 mL/s. The dynamic CT imaging setup captures CT images at a frequency of 2.5 Hz and resolution of 0.2 x 0.2 x 0.625 mm. The results are given in two forms: 1. The .am files are CT images with numbers in chronological order starting at time t=0, then 0.4 s, 0.8 s, and so on. The files are in .am format that can be opened using the software Amira. 2. The injection force required to maintain the flow rate is given in the form of .csv file named 'Injection_Force'. |
Methodology and Processing |
|
Sources Statement |
|
Data Access |
|
Other Study Description Materials |
|
Related Studies |
|
Trivedi, Zubin, 2021, "Measuring the viscoelastic properties and curing characterstics of Vertecem V+ bone cement using oscillatory rheometer", <a href="https://doi.org/10.18419/darus-2032">https://doi.org/10.18419/darus-2032</a>, DaRUS |
|
File Description--f64628 |
|
File: Injection_Force.tab |
|
|
|
Notes: |
UNF:6:H7VS7vaCTD5/iVSCIXdACQ== |
List of Variables: |
|
Variables |
|
f64628 Location: |
Variable Format: character Notes: UNF:6:PUsfoWL3WbzqpyVo+cB6gQ== |
f64628 Location: |
Variable Format: character Notes: UNF:6:ZZHTZaGeCipaOYrpZ3XLAw== |
f64628 Location: |
Variable Format: character Notes: UNF:6:gbNi8z8xG5TRi/SqGvriWw== |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_01.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_02.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_03.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_04.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_05.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_06.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_07.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_08.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_09.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_10.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_11.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_12.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_13.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_14.am |
Notes: |
application/octet-stream |
Label: |
CemFlow-03-Foam-03-Cine-40mm-0.4s-0.625-bone+_15.am |
Notes: |
application/octet-stream |
Label: |
Injection_Force.xlsx |
Notes: |
application/vnd.openxmlformats-officedocument.spreadsheetml.sheet |