Sample 1 of human femoral heads: micro-XRCT data sets (doi:10.18419/darus-1177)

View:

Part 1: Document Description
Part 2: Study Description
Part 5: Other Study-Related Materials
Entire Codebook

Document Description

Citation

Title:

Sample 1 of human femoral heads: micro-XRCT data sets

Identification Number:

doi:10.18419/darus-1177

Distributor:

DaRUS

Date of Distribution:

2021-03-30

Version:

1

Bibliographic Citation:

Ruf, Matthias; Steeb, Holger; Gebert, Johannes; Schneider, Ralf; Helwig, Peter, 2021, "Sample 1 of human femoral heads: micro-XRCT data sets", https://doi.org/10.18419/darus-1177, DaRUS, V1

Study Description

Citation

Title:

Sample 1 of human femoral heads: micro-XRCT data sets

Identification Number:

doi:10.18419/darus-1177

Authoring Entity:

Ruf, Matthias (University of Stuttgart, Institute of Applied Mechanics (CE))

Steeb, Holger (University of Stuttgart, Institute of Applied Mechanics (CE) & SimTech)

Gebert, Johannes (University of Stuttgart, High-Performance Computing Center)

Schneider, Ralf (University of Stuttgart, High-Performance Computing Center)

Helwig, Peter (Klinik Heidenheim)

Other identifications and acknowledgements:

Ruf, Matthias

Other identifications and acknowledgements:

Steeb, Holger

Producer:

University of Stuttgart, Institute of Applied Mechanics (CE) - Chair for Continuum-Mechanics

University of Stuttgart - SC SimTech

Date of Production:

2020-11-25

Distributor:

DaRUS

Access Authority:

Steeb, Holger

Access Authority:

Schneider, Ralf

Holdings Information:

https://doi.org/10.18419/darus-1177

Study Scope

Keywords:

Computer and Information Science, Engineering, Medicine, Health and Life Sciences, Human femoral head, micro X-ray Computed Tomography (micro-XRCT), High Performance Computing (HPC)

Abstract:

Data contains micro X-Ray Computed Tomography (micro-XRCT) data sets of an explanted femoral head. This specimen was donated by a male patient at the age of 74 and a bodyweight of 128 kg who received a hip endoprosthesis. Additional information was not given. The explantation took place in cooperation with Prof. Dr. Peter Helwig at the Clinic Heidenheim, southern Germany.<br> <br> The human femoral head was unfrozen before performing the micro-XRCT scans. We acquired three micro-XRCT data sets with two different geometric magnifications (resolutions). The data set "reconstructed_20201125_01.rar" is an overview scan of almost the entire human femoral head. The data sets "reconstructed_20201126_01.rar" and "reconstructed_20201127_01.rar" provide a detailed view of the center region. "reconstructed_20201126_01.rar" shows the lower part and "reconstructed_20201127_01.rar" the upper part of "reconstructed_20201125_01.rar".

Kind of Data:

Image data

Methodology and Processing

Sources Statement

Data Access

Other Study Description Materials

Related Studies

Gebert, J., Schneider, R., Helwig, P., & Schenkengel, J.-P. (2021). HLRS_Helwig_2020_Hueftkopf_01_B40f: A clinical computed tomography scan of a human femoral head. DaRUS. <a href="https://doi.org/10.18419/DARUS-1182">https://doi.org/10.18419/DARUS-1182</a>

Other Reference Note(s)

Ruf, M., & Steeb, H. (2020). An open, modular, and flexible micro X-ray computed tomography system for research. <em>Review of Scientific Instruments</em>, 91(11), 113102. <a href="https://doi.org/10.1063/5.0019541">https://doi.org/10.1063/5.0019541</a>

Other Study-Related Materials

Label:

reconstructed_20201125_01.rar

Text:

Reconstructed micro-XRCT data set in 16 bit *.tif file format. 2940x2940x2141 voxels with the uniform voxel size of 15.0 µm. Overview scan.

Notes:

application/x-rar-compressed

Other Study-Related Materials

Label:

reconstructed_20201126_01.rar

Text:

Reconstructed micro-XRCT data set in 16 bit *.tif file format. 2940x2940x2141 voxels with the uniform voxel size of 5.0 µm. Lower part scan.

Notes:

application/x-rar-compressed

Other Study-Related Materials

Label:

reconstructed_20201127_01.rar

Text:

Reconstructed micro-XRCT data set in 16 bit *.tif file format. 2940x2940x2141 voxels with the uniform voxel size of 5.0 µm. Upper part scan.

Notes:

application/x-rar-compressed