Title: |
micro-XRCT data set of Carrara marble with artificially created crack network: fast cooling down from 600°C |
Identification Number: |
doi:10.18419/darus-682 |
Distributor: |
DaRUS |
Date of Distribution: |
2020-06-22 |
Version: |
1 |
Bibliographic Citation: |
Ruf, Matthias; Steeb, Holger, 2020, "micro-XRCT data set of Carrara marble with artificially created crack network: fast cooling down from 600°C", https://doi.org/10.18419/darus-682, DaRUS, V1 |
Citation |
|
Title: |
micro-XRCT data set of Carrara marble with artificially created crack network: fast cooling down from 600°C |
Identification Number: |
doi:10.18419/darus-682 |
Authoring Entity: |
Ruf, Matthias (University of Stuttgart, Institute of Applied Mechanics (CE)) |
Steeb, Holger (University of Stuttgart, Institute of Applied Mechanics (CE) & SimTech) |
|
Other identifications and acknowledgements: |
Ruf, Matthias |
Other identifications and acknowledgements: |
Steeb, Holger |
Producer: |
University of Stuttgart, Institute of Applied Mechanics (CE) - Chair for Continuum-Mechanics |
University of Stuttgart - SC SimTech |
|
Date of Production: |
2019-11-20 |
Grant Number: |
STE 969/13-1 |
Grant Number: |
EXC 2075 - 390740016 |
Grant Number: |
SFB 1313 ‐ 327154368 |
Distributor: |
DaRUS |
Access Authority: |
Steeb, Holger |
Holdings Information: |
https://doi.org/10.18419/darus-682 |
Study Scope |
|
Keywords: |
Computer and Information Science, Earth and Environmental Sciences, Engineering, Carrara Marble, Micro X-Ray Computed Tomography (micro-XRCT), Cracks, Fractures, Rock Mechanics, Thermal Quenching |
Abstract: |
micro-XRCT data set (projection and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following thermal treatment to initiate cracks: <br> Starting at room temperature (20°C) the sample was heated up with a rate of 3 K/min to 600°C. After a holding time of 2 hours at this temperature, the sample was subsequently quenched in water at room temperature (20°C). |
Kind of Data: |
Image data |
Methodology and Processing |
|
Sources Statement |
|
Data Access |
|
Other Study Description Materials |
|
Related Studies |
|
Ruf, M., & Steeb, H. (2021). Effects of thermal treatment on acoustic waves in Carrara marble: measurement data. DaRUS. <a href="https://doi.org/10.18419/DARUS-1862">https://doi.org/10.18419/darus-1862</a> |
|
Related Publications |
|
Citation |
|
Title: |
Ruf, M., & Steeb, H. (2020). An open, modular, and flexible micro X-ray computed tomography system for research. <em>Review of Scientific Instruments</em>, 91(11), 113102. |
Identification Number: |
10.1063/5.0019541 |
Bibliographic Citation: |
Ruf, M., & Steeb, H. (2020). An open, modular, and flexible micro X-ray computed tomography system for research. <em>Review of Scientific Instruments</em>, 91(11), 113102. |
Citation |
|
Title: |
Ruf, M., & Steeb, H. (2022). Effects of thermal treatment on acoustic waves in Carrara marble. <em>International Journal of Rock Mechanics and Mining Sciences</em>, 159, 105205. |
Identification Number: |
10.1016/j.ijrmms.2022.105205 |
Bibliographic Citation: |
Ruf, M., & Steeb, H. (2022). Effects of thermal treatment on acoustic waves in Carrara marble. <em>International Journal of Rock Mechanics and Mining Sciences</em>, 159, 105205. |
Label: |
projections.rar |
Text: |
Projection images (360 deg, angle increment 0.2 deg), dark image (di) and open beam image (ob) in 16 bit *.tif file format. |
Notes: |
application/x-rar-compressed |
Label: |
reconstructed.rar |
Text: |
Reconstructed micro-XRCT data set in 16 bit *.tif file format. 2940x2940x2139 voxels with the uniform voxel size of 1.9996 µm. |
Notes: |